Monitor the production and to automize data logging.
IFS/HACCP REPORT
The IFS/HACCP REPORT shows detailed information about the production. It consists of three parts that are described below:
SUMMARY, METAL, EVENTS.
You can switch between the different types with +/-.
Press ⯅⯆ to can scroll up and down.
Press ESC to return to the main menu.
Press OK to print the IFS/HACCP REPORT.
Note: Set REPORT MENU > PRINT to report to set up a printer connected to the RS232 interface.

The SUMMARY shows the following information:
From date/time: | Indicates when the last report was printed. |
To date/time: | Indicates the current time and date. |
Number of passed PVS tests: | Indicates the number of PVS test that were completed accordingly. |
Number of failed PVS tests: | Indicates the number of PVS test that were not completed accordingly. |
Metal Events: | Indicates the number of metal events that have occurred since the last report was printed. |
Product Counter: | Indicates the number of products that have gone through the sensor since the last report was printed. |
Percent Metal: | Indicates the ratio (%) of contaminated products to the total number of products. |

METAL shows detailed information about the specific metal events (max last 1024 events).
Here an example of how to read the list:
0034 | number of the metal alarm |
2008-05-05 | date the alarm occurred |
17:22:24 | time the alarm occurred |
P005 | product number |
245 mV | voltage that was measured |
132.88° | phase that was measured |

EVENTS shows all events (e.g. changes of settings, status updates for TEACH, error messages) since the last print out (max last 1024 events).
Here an example of how to read the list:
0001 | number of the event |
2008-05-05 | date of the event |
17:22:24 | time of the event |
[01] | code for the respective type of event |
System started | Indicates which setting was changed or what action was taken. |
METAL REPORT
METAL REPORT shows the same information like the IFS/HACCP REPORT – METAL plus two additional details. Press + to display these.
Press ⯅⯆ to scroll up and down.
Press ESC to return to the main menu.
Press OK to print the METAL REPORT.
Note: Set the parameter PRINT to report to set up a printer connected to the RS232 interface.

The two additional details are:
600000 Hz | sensor frequency for this product |
12%/800% | amplification of X and Y for this product |
Characters at the end of a metal report line are for diagnose purposes:
D = Detect M Signal Clipping (directly at the receiver coil).
R = RFP Clipping
S = Saturated raw signal at the A/D converter. Decrease AMPLIFICATION % for X and Y or set an ATTENUATION of 1/3 or 1/10.
! = with photo sensor: Metal detection without a suitable photo sensor interruption in this area.
Click here for Metal Reports Diagnose Info
EVENT REPORT
EVENT REPORT shows the same information like the IFS/HACCP REPORT – EVENTS (e.g. changes of settings, status updates for TEACH, error messages). However, the data is not deleted at any time. The last 1024 events are always listed.
Press ⯅⯆ to scroll up and down.
Press ESC to return to the main menu.
Press OK to print the EVENT REPORT.


Note: Set the parameter PRINT to report to set up a printer connected to the RS232 interface.
Comments 1