Password administration for different access level.
Level 1: e.g. for operators Level 2: e.g. for production manager and quality manger Level 3: e.g. for company technician
Automatic Logout
The SHARK2 falls back to the user level set at OPEN LEVELS when:
the SHARK2 power supply is switched off,
or LOGOUT is pressed,
or after 30 minutes without pressing any key.
OPEN LEVELS | Set which password level are open without having to enter a specific password. |
LEVEL 1 PASSWORD | Set the password for level 1 users, e.g. production line operators. Level 1 users are allowed to SELECT products and TEST the metal detector’s functionality. Default: CM0001 |
LEVEL 2 PASSWORD | Set the password for level 2 users, e.g. production or quality managers. Level 2 users are allowed to TEACH and OPTIMIZE products, print reports and set up TEST. Default: CM0002 |
LEVEL 3 PASSWORD | Set the password for level 3 users, e.g. company technicians. Level 3 users are allowed to access and alter settings in the PRODUCT MENU and SYSTEM MENU. Default: CM0003 |
RESET PW LEVEL | Set the password level required to quit metal alarms and errors |
LOGOUT | Locks all password levels that are higher than the level set for the parameter OPEN LEVELS. Use this function when you are done with your settings to prevent others from changing any settings. |
LICENSE EXPIRES | Preset by Cassel factory. In case the license has expired, the metal detector is no longer operational. Access requires user level 4 with Cassel master password. By default, LICENSE EXPIRES is set to NO. This means that the license will never expire. When LICENSE EXPIRES is set to YES, the license will be valid for the number of days set by EXPIRATION DAYS, then a LICENSE ERROR will occur, and the SHARK2 will no longer be operational. In case LICENSE ERROR occurs: Please contact Cassel to obtain the license number. |
EXPIRATION DAYS | Shows remaining operation days before the license expires. Note that the operating time of the device is counted, not the real time. When the SHARK2/2A is shut down, the time does not count. The counted time starts when one of the parameters LICENSE EXPIRES or EXPIRATION DAYS has been altered. Range: 1-999 When less than 10 operation days are left, the SHARK2/2A shows a yellow warning in the top notification bar (if no other warnings are active) More information on how to to obtain a licence code: https://docs.cassel-inspection.com/md/howto-license-code |