Belt Splice Detector GN2

Installation Manual – Belt splice detector GN2 (metal splice) #10250039. The belt splice detector is optional equipment. When a metal belt splice passes the metal detector, it sets the metal sensitivity to a less sensitive threshold.

Installation Manual – Belt splice detector GN2 (metal splice) #10250039

1. General information

The belt splice detector is optional equipment. When a metal belt splice passes the metal detector, it sets the metal sensitivity to a less sensitive threshold.

2. Mechanical installation

Install the belt splice detector as pictured below.

Switching distance

Adjust the switching distance with the potentiometer. The switching distance can also be seen as sensitivity of the belt splice detector.

Distance between belt splice detector and metal detector

3. Electrical installation

4. Parameter settings

Belt splice setup

Open MENU > SYSTEM MENU > IN/OUT MENU

Set INPUT LINE 8 to ‘belt splice’

Open MENU > SYSTEM MENU > BELT SPLICE SETUP

Link to BELT SPLICE SETUP function reference

5. Function tests

Test 1: When the metal splice passes the belt splice detector, the LED lamp lights up (red circle).

Test 2: Open MENU > SYSTEM MENU > IN/OUT MENU

When the metal splice passes the belt splice detector, the „0“ changes to „1“ (red frames) and the OK in the top left corner turns from green to orange.

Test 3: Open MENU > PRODUCT MENU > ADVANCED

When the metal splice passes the belt splice detector, the METAL SENSE mV changes (red frames).

Comments 1