The CIP MENU (CIP = Clean In Place) is for pipeline models only (METAL SHARK® IN LIQUID).
If activated, the reject device toggles between positions “NORMAL” (production) and “REJECT” as long as the CIP input is in state HIGH. Cleaning fluid running through the product pipes cleans all interior surfaces of the reject device.
CIP Reject s
sets the time for how long the reject device is switched to position “REJECT” (in seconds).
Default: 0
Range: 0 – 320 [Seconds]
CIP Normal s
sets the time for how long the reject device is switched to position “NORMAL” (in seconds)
Default: 0
Range: 0 – 999 [Seconds]
CIP Timeout min
sets the maximum time the detector is in CIP-mode (in minutes). After this time, the detector will switch to normal operation even if CIP input remains HIGH. Next CIP can be activated only after CIP input has been reset to low.
Note: Refer to parameter start cip in IN/OUT MENU.
Default: 1
Range: 1 – 999 [Minutes]