MD

PRINT

Protocol mode for optional printer.

| Comments Off on PRINT

Multiphase +/-

Maximum tolerance or deviation for the product phase. Any product drift within this tolerance will automatically be compensated.

Backup

Used to store and restore SHARK settings.

| Comments Off on Backup

BOOST FACTOR

Improves detection strength of small metals in certain situations, especially at product front and tail.

HowTo: License Code

Obtain and enter a license code with SHARK2/2A metal detectors. LICENSE ERROR indicates that the license or demo period has expired.

BIG METAL mV

Set another threshold to detect only big metal parts. The big metal detections are signalled on a separate output 'big metal'.

| Comments Off on BIG METAL mV

PROD. TIMEOUT s

Automatic decrease of sensitivity. Typical application for cleaning processes of metal detectors type IN-Liquid

| Comments Off on PROD. TIMEOUT s

PHASE TRACK

Adjusts the product's phase during normal operation to compensate slow changes of the product effect phase.

| Comments Off on PHASE TRACK