Multiphase TOL. X*/Y*
Additional scale factor to automatically scale TOL. X and TOL. Y during teaching a product.

BOOST FACTOR
Improves detection strength of small metals in certain situations, especially at product front and tail.

HowTo: License Code
Obtain and enter a license code with SHARK2/2A metal detectors. LICENSE ERROR indicates that the license or demo period has expired.

BIG METAL mV
Set another threshold to detect only big metal parts. The big metal detections are signalled on a separate output 'big metal'.

PROD. TIMEOUT s
Automatic decrease of sensitivity. Typical application for cleaning processes of metal detectors type IN-Liquid

PHASE TRACK
Adjusts the product's phase during normal operation to compensate slow changes of the product effect phase.

PHASE
The setting of the product phase helps to blank out any product effect. It is set automatically during the TEACH process.